a, Cores and sections
1, 2, 3, 3+1, 3+2, 3+3, 4, 4+1, 4+2, 5 and so on.
No. Of Core and Sectional Area(mm2) :
1 Core 1.5-800 25-800 25-1200 25-1200 35-1200 50-1200 50-1200 50-1200
2 Core 1.5-185 25-185
3 Core 1.5-400 25-400 25-400 25-400 35-400 50-400 50-400 50-400
4 Core 2.5-400 25-400
5 Core 2.5-400 25-400
b Energy Cable Construction :
Conductor: Solid or stranded copper
Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)
Filler: Polypropylene filament with lapped binding tape
Binder: Binding tape
Inner sheath: Polyvinyl chloride (PVC)
Amour: Galvanized steel wire armored(SWA) or steel tape armored(STA)
Sheath: Polyvinyl chloride (PVC)
c, Energy Cable Nominal Section:
Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800
d.Energy Cable Operating Features :
1)The maximum conductor operating temperature: 90°C
During short circuit (lasting less than 5 seconds) the maximum temperature of the cable conductor shall not be above 250°C
Environment temperature should be no lower than 0°C for laying the cable.
2)Bending Radius of the Cable:
Single Core Cable: Non Armored Cable 20D, Armored Cable 15D
Cores Cable: Non Armored Cable 15D, Armored Cable 12D.
Remarks: D means practical external diameter of the cable
e, Energy Cable Features :
XLPE insulated steel wire armoured power cable: XLPE/PVC insulated power cable has a number of advantages over paper insulated and PVC insulated cable. XLPE cable has high electric strength, mechanical strength, high-ageing resisting, environmetal stress resisting antichemical corrossion, and it is simple construction, using convenient and higher operating of long term temperature. It can be laid with no drop restriction.
Various of flame-retardant and non-flame retardant XLPE cable can be manufactured with three technology(peroxide, silane and irradiation crosslinking). The flame-retardant cable covers all kinds of low-smoke low-halogen low-smoke halogen free, and non-smoke nonhalogented and three classes of A, B, C.
2 Standard:
IEC60502,and BS6346, VDE, AS/NZS, UL,etc or as customer's request.
3 The Rated Voltage(kv):
1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 - 26/35
4 Application:
1)These cables are most suitable for direct burial or for installation on trays or ducts, Where there is
a risk of mechanical damage, armoured cables should be used.
2) For laying in ground along route with large difference of level able to bear external mechanical forces.
Energy Cable Product Details.
Reference Standards: |
IEC60502-2, IEC 60228, IEC60332 -1/2/3, BS6622, BS7835, VDE0276, AS/NZS 1429.1, GB/T 12706, etc. |
Rated Voltage: |
6/10kV, 6.35/11kV (12kV), 8.7/15kV, 12/20kV, 18/30kV,19/33kV |
Core Number: |
Single Core or Three Core (1C or 3C) |
Available Dimensions: |
25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2, 630mm2. |
Codes Available: |
N2XSY, N2XSEY, NA2XSY, NA2XSEY, N2XSRY, NA2XSRY, N2XSEBY, N2XSEYBY, NA2XSEBY, N2XSERY, NA2XSERY, N2XSEYRGbY, NA2XSEYRGbY, N2XS(F)2Y, NA 2XS(F)2Y, N2XS(FL)2Y, N2XSH, N2XSYRY |
YJV, YJLV, YJSV, YJLSV, YJV72, YJLV72, YJSV72, YJLSV72, YJV22, YJLV22, YJSV22, YJLSV22, YJV32, YJLV32, YJSV32, YJLSV32 |
|
Application: |
For power networks, underground, outdoors and in cable ducting. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed, so that the safeguarding of persons and the integrity of the product will not be affected during installation. |
Construction: |
|
Conductor: |
Stranded round compacted copper or aluminum conductor (Cu / Al ), copper wire annealed. |
Conductor Screen: |
Semi-conducting material |
Insulation: |
XLPE (Cross-Linked Polyethylene) |
Insulation Screen: |
Semi-conducting material |
Metallic Screen: |
Copper tape screen or copper wire screen (CTS / CWS ) |
Filler: |
PP rope |
Separator: |
Binding tape |
Bedding: |
PVC (Polyvinyl Chloride) |
Armouring: |
Single Core: Aluminium Wire Armoured (AWA) Multi-core: Steel Wire Armoured (SWA) or Steel Tape Armoured (STA) |
Sheath: |
PVC (Polyvinyl Chloride), flame retardant PVC, PE, LSOH, HFFR |
Colour: |
Red or Black |
Temperature Rating: |
0°C to 90°C |
Minimum Bending Radius: |
Single Core: 15 x overall diameter Three Core: 12 x overall diameter (Single Core 12 x overall diameter and 3 core 10 x overall diameter where bands are positioned adjacent to joint or terminations provided that the bending is carefully controlled by the use of a former |