1. 0.6/1KV. Rated voltage: Up to and including 0.6/1(1.2)kV;
2. Conductor: Pure annealed copper or aluminum.
3. Insulation: XLPE/PE/PVC.
4. Cores: 1 C, 2C, 3C, 4C.
5. Nominal Cross-section: 10mm2 to 400mm2.
6. Standard: GB/T 14049-2008 IEC 60502.
7. Max. Operating Temperature: XLPE/PE: 90 °C , PVC : 70 °C .
8. Type: ABC Cable, JKTRYJ, JKLYJ,JKTRY, JKLY, JKLGYJ, JKLGY, JKLYJ/Q, JKLY/Q, JKLGYJ/Q, JKLGY/Q.
9. Packing: Wooden Drum or according to the customer requirement.
10. Remark: The cable can be of flame retardant, fire resistance and other property.
Overhead cable.
For single core PVC or XLPE insulated or covered aerial cable without messenger or neutral conductor,
the phase conductor may be AAC or AAAC or ACSR or Copper.
For more than one core PVC or XLPE insulated 11kv abc cable with or without messenger or neutral conductor and with or without street lighting conductor, the phase conductor and street lighting conductor are AAC with PVC insulation,and the messenger or neutral conductor is AAAC or ACSR with or without
temperature of conductor during short-circuit ( 5s max. duration) shall not exceed: 250oC(XLPE insulated), 130 oC (PE insulated), 160 oC (PVC insulated); 11kv abc cable The ambient temperature under installation should not be lower than: -20 oC.
Application of Overhead abc cable.
PVC or XLPE insulated 11kv abc cable as a new-type aerial cable is used for overhead electric power transmission,
extensively used in rebuilding of urban and forest region electrified wire netting. It improves the safety and reliance of electrified wire netting.
1. Overhead Transmission 3x70mm 3cores x35 3x25+54.6 abc cable Construction.
Code*Word | Phase conductor | Bare Neutral Message | Nominal lay Length |
Weight Per 1000 ft.(lbs.) |
Allo wable Amp acitles | ||||||
Size (A WG) |
Stranding |
Insul Thick(Mils) |
Size (AWG) |
Stranding |
Rated Strength (lbs.) |
inches | XLP | POLY | XLP | POLY | |
AAC Neutral-messenger | |||||||||||
Pekingese | 6 | 1 | 45 | 6 | 7 | 563 | 10.36 | 61 | 61 | 85 | 70 |
Collie | 6 | 7 | 45 | 6 | 7 | 563 | 10.36 | 64 | 64 | 85 | 70 |
Dachshund | 4 | 1 | 45 | 4 | 7 | 881 | 10.36 | 92 | 92 | 115 | 90 |
Spaniel | 4 | 7 | 45 | 4 | 7 | 881 | 10.36 | 96 | 96 | 115 | 90 |
Doberman | 2 | 7 | 45 | 2 | 7 | 1350 | 14.88 | 147 | 147 | 150 | 120 |
Malemute | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 14.88 | 234 | 234 | 205 | 160 |
Overhead Transmission 3x70mm 3cores x35 3x25+54.6 abc cable . .
a.Application
Used to supply 3-phase power,usually from a pole-mounted transformer,to the user's service head where connection to the service entrance cable is made.To be used at voltage of 600 volts phase-to-phase or less and at conductor temperature not to exceed 75 for polyethylene insulated conductors or 90 for crosslinked polyethylene(XLP) insulated conductors.
b.Construction
Code*Word | Phase conductor | Bare Neutral Message | Nominal lay Length |
Weight Per 1000 ft.(lbs.) |
Allo wable Amp acitles | ||||||
Size (A WG) |
Stranding |
Insul Thick(Mils) |
Size (AWG) |
Stranding |
Rated Strength (lbs.) |
inches | XLP | POLY | XLP | POLY | |
AAC Neutral-messenger | |||||||||||
Clydessdale | 4 | 1 | 45 | 4 | 7 | 881 | 20.58 | 198 | 198 | 100 | 80 |
Pinto | 4 | 7 | 45 | 4 | 7 | 881 | 20.58 | 211 | 211 | 100 | 80 |
Mustang | 2 | 7 | 45 | 2 | 7 | 1350 | 25.42 | 318 | 318 | 135 | 105 |
Criollo | 1/0 | 9 | 60 | 1/0 | 7 | 1990 | 25.42 | 503 | 503 | 180 | 140 |
Percheron | 2/0 | 11 | 60 | 2/0 | 7 | 2510 | 29.97 | 619 | 619 | 205 | 160 |
Hanovarian | 3/0 | 17 | 60 | 3/0 | 19 | 3310 | 35.18 | 764 | 764 | 235 | 185 |
Oldenburg | 4/0 | 18 | 60 | 4/0 | 19 | 4020 | 35.18 | 945 | 945 | 275 | 210 |
Lippizaner | 336.4 | 19 | 80 | 336.4 | 19 | 6146 | 38.79 | 1519 | 1519 | 370 |
280 |