1) The type of this fiber with single-mode or multi mode with a loose tube which is made of high modulus plastic .there is used a water-resistant filling compound for filling.
3) the center used a steel wire locates as a metallic strength member .for some cable ,a steel wire sometimes sheathed with polyethylene .the tubes ( and filers ) are stranded around the strength member into a compact and circular cable core.double sides chromium for PSP with PE as sheath .
3) by single or double wire for installation ,also with PE for outer sheath.
♦ PE outer sheath provide excellent ultraviolet radiation resistant property
♦ After the optical fiber ,the additional attenuation close to zero,no changed dispersion.
♦ Good moisture-resistance
♦ Control of fiber excess length stability.
Main specifications for opgw production line :
Cable model |
OPGW-60 |
OPGW-70 |
OPGW-90 |
OPGW-110 |
OPGW-130 |
Number /diameter(mm) of stainless steel tube |
1/3.5 |
2/2.4 |
2/2.6 |
2/2.8 |
1/3.0 |
Number /diameter of AL wire(mm) |
0/3.5 |
12/2.4 |
12/2.6 |
12/2.8 |
12/3.0 |
Number /diameter of ACS wire(mm) |
6/3.5 |
5/2.4 |
5/2.6 |
5/2.8 |
6/3.0 |
Diameter of Cable (mm) |
10.5 |
12.0 |
13.0 |
14.0 |
15.0 |
RTS(KN) |
75 |
45 |
53 |
64 |
80 |
Cable weight (kg/km) |
415 |
320 |
374 |
432 |
527 |
DC resistance(200C W/km) |
1.36 |
0.524 |
0.448 |
0.386 |
0.327 |
Modulus of elasticity(Gpa) |
162.0 |
96.1 |
95.9 |
95.6 |
97.8 |
coefficient of Linear thermal expansion(1/°C×10-6) |
12.6 |
17.8 |
17.8 |
17.8 |
17.2 |
Short circuit capacity (kA²s) |
24.0 |
57.3 |
78.9 |
105.8 |
150.4 |
Max. operation temperature (°C) |
200 |
200 |
200 |
200 |
200 |
Max. fiber count |
48 |
32 |
48 |
|
|