IEC Standard KVV/KVV22/KVVP/KVVR/KVVRP control cable

IEC Standard KVV/KVV22/KVVP/KVVR/KVVRP control cable specification:
1.Copper Conductor, XLPE Insulated, Braiding Shielded, PVC Sheathed Flexible Control Cable 

GB9330-1988,IEC,DIN,BS,450/750V AC

2,450/750V Copper Coductor PVC Insulated and sheathed Flexible Control Cable
Detailed Product Description

3,The control cable can be produced according to the standard GB9330-1988,IEC,DIN,BS,and the factory can also manufacture the cables in accordance with other standards.


4,The control cable are suitable for the wiring of electrical controlling equipments and instrument,monitoring and controlling return circuit,electrical protection and measurement in power distribution unit under the circumstance that the rated voltage is up to 450/750V AC.

 

5,Maximum operation voltage: 600 V.

6,Maximum operation temperature in the conductor: 

90°C In a dry environment. 
75°C In a wet environment.

 

7,Soft drawn concentric lay stranded copper conductor class B (7 wires).

 

8,Manufactured in sizes from 0,823 5 to 5,26 mm2 (18 to 10 AWG).

 

9,No-flame propagation characteristics.

 

10,Polyvinyl Chloride (PVC) insulation and jacket with low smoke emission and low acid gas content characteristics. 
Black outer jacket.

 

11,Con. Multiple-cond. THW-LS / THHW-LS Con. Multiple-cond. THWN / THHN Con. PE + PVC type 
Control EPR + CPE Type Control EPR + PVC Type Control XLPE + PVC 
Control Zero Halogens LS PVC + PVC type LS PVC + PVC type / shielded cables

 

0.6 / 1kv control cable Name

Section Area(mm2)

No. of Core

0.6 / 1kv control cable Application Site

Copper Conductor,PVC Insulated and Sheathed Control Cable

0.75 1.0 1.5 2.5

2-16

Permanent installation indoors,in cable ditches or pipes

4 6

2-14

10

2-10

Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded  Control Cable

0.75 1.0 1.5 2.5

2-61

Permanent installation indoors,in cable ditches or pipes where shielding is required

4 6

2-14

10

2-10

Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable

0.75 1.0 1.5 2.5

4-10

Permanent installation indoors,in cable ditches or pipes where shielding is required

4 6

7-61

10

4-10

Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable

0.75 1.0 1.5 2.5

7-61

Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force

4 6

4-14

10

4-14

Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable

0.5-2.5

4-61

Installation indoors where flexibility and movability are required

Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable

0.5 0.75 1.0

4-61

Installation indoors where flexibility shielding and movability are required

1.5 2.5

4-48

Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable

0.75 1.0 1.5 2.5

2-16

Permanent installation indoors,in cable ditches or pipes

4 6

2-14

10

2-10

  • Inqury